Open product image ↗Outdoor vacuum boundary circuit breaker for overhead distribution branches.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
ZW32 is an outdoor vacuum circuit-breaker arrangement for overhead distribution and customer-boundary applications. With the selected controller, it can provide monitoring and coordinated fault-protection functions. Network grounding, fault-detection requirements and upstream protection must be considered together.

For selected branch and customer-boundary switching duties.

For installations requiring configured fault detection, status monitoring and communication functions.

The breaker provides the selected outdoor switching duty using vacuum interruption. Rated duties and environmental suitability must be matched to the installation.
Overcurrent, short-circuit and ground-fault functions depend on the selected controller and network conditions. The protection-function list should be agreed explicitly.
An isolator option is identified within the model arrangement. Required visible isolation and operating interlocks should be specified with the complete assembly.
Fault isolation and any automation sequence require coordination with upstream and downstream devices. Grounding method affects the protection design.
Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.
Illustrative working sceneState any different ambient temperature, altitude, humidity, dust, salt or corrosive exposure when requesting the installation-specific configuration.
Review the listed configuration and applicable units. On a small screen, scroll the table sideways.
| Parameter | Catalogue value |
|---|---|
| Rated voltage | 12 kV |
| Rated current options | 630 / 1,250 A |
| Rated frequency | 50 Hz |
| Dry 1 min withstand, phase/earth and open gap | 42 / 48 kV |
| Wet 1 min withstand, external insulation | 34 kV |
| Short-circuit breaking current options | 20 / 25 kA |
| Peak withstand/making current options | 50 / 63 kA |
| Short-time withstand (4 s) options | 20 / 25 kA |
| Mechanical life stated in catalogue | 10,000 operations |
| Secondary-circuit 1 min withstand | 2 kV |
Checked against original distribution catalogue PDF page 51. 20 and 25 kA variants correspond to 50 and 63 kA peak ratings. The impulse entry with conflicting units is excluded. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.
Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Specify electrical duty, installation arrangement and the required protection coordination.
Model lists & repeat orders
Discuss supply requirements ↗List complete breaker variants, pole counts, control voltages and accessory combinations.
Equipment integration & matching
Discuss an assembly ↗Provide mounting, terminals, operating mechanism and secondary wiring interfaces.
Identify an existing unit or part
Identify a replacement ↗Start with the complete nameplate and photos of terminals, mounting, secondary plug and accessories.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Voltage designation: 12 kV
View specifications ↗
Voltage designation: 7.2–12 kV
View specifications ↗
Voltage designation: 12 kV
View specifications ↗
Voltage designation: Low voltage