Outdoor distribution feeders
For urban, rural and industrial overhead distribution duties.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗Outdoor vacuum circuit breaker with a sealed enclosure for distribution automation.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
ZW20 is an outdoor vacuum circuit breaker with a sealed enclosure arrangement using SF6 insulation. Vacuum interruption and enclosure insulation perform different functions in this design. The selected mechanism, controller and protection arrangement determine the complete operating scope.

For urban, rural and industrial overhead distribution duties.

For installations requiring controller-based protection and, where specified, reclosing or remote monitoring.

The current-interruption function uses vacuum interrupters; the sealed enclosure uses SF6 for insulation. These functions should be identified correctly in the equipment specification.
The enclosure and connection arrangement are selected for the outdoor installation. Site conditions and required environmental performance should be stated.
The described design uses a spring operating mechanism. Operating supply and secondary functions must match the installation control scheme.
Protection, communication and reclosing functions require the selected controller and settings. They are not implied by the breaker designation alone.
Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.
Illustrative working sceneState any different ambient temperature, altitude, humidity, dust, salt or corrosive exposure when requesting the installation-specific configuration.
Review the listed configuration and applicable units. On a small screen, scroll the table sideways.
| Parameter | Catalogue value |
|---|---|
| Rated voltage | 12 kV |
| Rated frequency | 50 Hz |
| Rated current options | 630 / 1,000 / 1,250 A |
| Short-circuit breaking current options | 20 / 25 kA |
| Peak withstand/making current options | 50 / 63 kA |
| Short-time withstand (4 s) options | 20 / 25 kA |
| Mechanical life stated in catalogue | 10,000 operations |
| Rated-current breaking operations stated | 10,000 operations |
| 1 min withstand, phase/earth and open gap | 42 / 48 kV |
| Lightning impulse, phase/earth and open gap | 75 / 85 kV |
| Secondary-circuit 1 min withstand | 2 kV |
| Catalogue net weight | 140 kg; up to 170 kg with isolating arrangement |
Checked against original distribution catalogue PDF page 52. 20 and 25 kA variants correspond to 50 and 63 kA peak ratings. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.
Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Specify electrical duty, installation arrangement and the required protection coordination.
Model lists & repeat orders
Discuss supply requirements ↗List complete breaker variants, pole counts, control voltages and accessory combinations.
Equipment integration & matching
Discuss an assembly ↗Provide mounting, terminals, operating mechanism and secondary wiring interfaces.
Identify an existing unit or part
Identify a replacement ↗Start with the complete nameplate and photos of terminals, mounting, secondary plug and accessories.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Voltage designation: 12 kV
View specifications ↗
Voltage designation: 7.2–12 kV
View specifications ↗
Voltage designation: 12 kV
View specifications ↗
Voltage designation: Low voltage
View specifications ↗Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English