XGW-12–24 kV · Outdoor ring-main unit

Modular outdoor ring-main assembly for 12/24 kV-class distribution.

Model voltage classes
12 / 24 kV
Assembly
Ring-main switching
Frequency
50 / 60 Hz
Gas compartment protection
IP67

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where XGW-12–24 kV fits

XGW outdoor switching stations combine a compact gas-insulated switching arrangement with an external enclosure. Incoming, outgoing, metering, bus-coupler and voltage-transformer functions are arranged around the network scheme. Automation can be included where the selected controller and communications support the required functions.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 01

Urban cable networks

For outdoor switching points providing a defined arrangement of incoming and outgoing circuits.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 02

Distribution automation

For network installations requiring switching status, electrical measurements and configured remote-control functions.

PRODUCT ENGINEERING

Construction & operating functions

XGW-12–24 kV product illustration
XGW-12–24 kVProduct illustration · Configuration varies by specification
DETAIL / 01

Unit-based switching scheme

Switching units are combined according to the incoming, outgoing and bus arrangement. Metering and voltage-transformer functions should be identified separately where required.

DETAIL / 02

External enclosure

The switching equipment is housed in an outer enclosure, with metal and non-metal constructions described. Access and site exposure determine the selected arrangement.

DETAIL / 03

Automation integration

FTU or RTU functions can collect switching status and electrical quantities. Remote operation requires the specified auxiliary supply, communication link and operating permissions.

DETAIL / 04

Civil interfaces

The foundation and cable layout need drainage, access and grounding provisions coordinated with the equipment arrangement. The installation drawing is part of the site design.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

SPECIFICATION & INTEGRATIONReview equipment installation

Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.

Illustrative working scene
Primary scheme
Specify the selected voltage class, circuit duties and unit arrangement.
Automation
Provide signal lists, protocol, communication medium and control-power requirements.
Site layout
Identify enclosure dimensions, cable ducts and maintenance access.

Installation & connection checklist

  • Submit the single-line diagram and cable schedule.
  • Confirm the exact selected voltage configuration.
  • Coordinate the foundation and drainage drawing with the installation designer.
  • Agree the automation point list and technical documents before ordering.

Technical sheets & drawings

Catalogue reference data for the labelled configuration. The agreed technical schedule defines the supplied equipment.

XGW installation dimensions · original PDF p.45 View referenceXGW installation dimensions · original PDF p.45
DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

XGW-12–24 kV product illustration
XGW-12–24 kV · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the network scheme, cable schedule, circuit quantities and site layout.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

List voltage classes, connection arrangements, enclosure options and recurring quantities.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Provide cable and bushing interfaces, mounting drawings and any switching or metering requirements.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Send connector markings, cable details, dimensions and photos of the existing assembly.

Illustrative enquiry scenarios.

Selection checklist for XGW-12–24 kV
  • System voltage, circuit count and cable sizes
  • Connector/bushing interface and cable insulation dimensions
  • Switching, metering, protection and surge-arrester requirements
  • Enclosure layout, mounting, foundation and site environment
  • Submit the single-line diagram and cable schedule.
  • Confirm the exact selected voltage configuration.
  • Coordinate the foundation and drainage drawing with the installation designer.
  • Agree the automation point list and technical documents before ordering.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Product catalogue

Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English

Download PDF ↗

For a quotation, include your required model, rating, quantity and operating conditions.