Skip to content
TRANSFORMERS & ELECTRICAL COMPONENTS
EV Charging Equipment & Parts

MK DC Split 480–1440 · 480–1,440 kW flexible DC charging system

480–1,440 kW flexible DC charging system

480–1,440 kW flexible DC charging system. Central power equipment and separate charging terminals for coordinated station deployment.

Brand
Mingkong
Model
MK DC Split 480–1440
Supply
Charging equipment supply
Power options
480 / 720 / 960 / 1200 / 1440 kW
Format
480–1,440 kW flexible DC charging system
Ingress protection
IP54

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where MK DC Split 480–1440 fits

480–1,440 kW flexible DC charging system from the Mingkong charging equipment range. Power cabinets and dispensing terminals are selected separately. Cabinet power must not be interpreted as the output available at every connector simultaneously.

Illustrative passenger-car charging bays
Application illustration
APPLICATION / 01

Public and commercial parking

For public charging stations, shopping-centre parking and commercial sites. Match the selected power and connector configuration to the available supply and expected vehicle dwell time.

Illustrative modular charging equipment at a logistics depot
Application illustration
APPLICATION / 02

Fleet and transport facilities

For taxi, commuter, logistics and other fleet charging requirements described in the catalogue. Provide the vehicle list, daily charging schedule and number of simultaneous sessions.

PRODUCT ENGINEERING

Construction & operating functions

MK DC Split 480–1440 product illustration
MK DC Split 480–1440Product illustration · Configuration varies by specification
DETAIL / 01

Shared power architecture

Power is pooled in a central cabinet and allocated to dispensing terminals. Select total installed power, terminal current classes and simultaneous charging demand as one system.

DETAIL / 02

Demand-based allocation

The catalogue describes allocation according to vehicle demand and battery status. The detailed control strategy and vehicle communication must be agreed for the project.

DETAIL / 03

Modular expansion

A modular architecture is described for staged expansion. Confirm installed modules, expansion headroom, bus capacity and cabinet limits in the offered configuration.

DETAIL / 04

Separate terminal selection

Air-cooled and liquid-cooled terminal alternatives are listed. Their current classes, connector counts, cable system and dimensions must be matched to the power cabinet.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

Illustrative engineer reviewing charging-equipment placement and installation interfaces
SPECIFICATION & INTEGRATIONPlan the charging installation

Review site supply, vehicle interfaces, cable reach, mounting and operating-platform requirements together.

Illustrative working scene
Supply and site integration
Confirm the site voltage, frequency, available transformer capacity and simultaneous charging demand. Upstream switchgear and cable selection depend on the final installation.
Vehicle connector and charging protocol
Select the required vehicle interface and charging protocol for the destination. Connector appearance alone does not establish compatibility.
Network and operating platform
Confirm the backend protocol/version, SIM or Ethernet arrangement, billing integration and user-access methods. Network connectivity does not by itself confirm backend compatibility.
Installation and delivery scope
Agree the charger or cabinet, terminals, cables, foundation interfaces, commissioning documents, spare parts and warranty scope in the quotation.

Installation & connection checklist

  • Provide the site single-line diagram, available AC supply, earthing arrangement and upstream protection.
  • Confirm vehicle connector standards, DC voltage range and required power per active outlet.
  • Provide foundation or wall details, cable routes, ventilation clearances and service access.
  • Specify the backend platform, network coverage, authentication methods and local payment requirements.
CHARGING SPECIFICATIONS

Power & technical data

Choose a power configuration, then review the matching supply, interfaces and installation requirements.

Mingkong catalogue referenceRated power (kW)Listed output current (A)Enquiry
MK DC Split 480–1440 / 480 kW480—Request this configuration ↗
MK DC Split 480–1440 / 720 kW720—Request this configuration ↗
MK DC Split 480–1440 / 960 kW960—Request this configuration ↗
MK DC Split 480–1440 / 1200 kW1200—Request this configuration ↗
MK DC Split 480–1440 / 1440 kW1440—Request this configuration ↗

Mingkong catalogue references identify the configuration for enquiries. Confirm the final ordering code, vehicle interface and technical schedule. Output current, voltage and simultaneous charging limits must be considered together. A dash means no confirmed value is published.

Separate charging terminals

Terminal classConnector arrangementDimensionsRated current
Air-cooled 250 ASingle / dual connector1480 × 400 × 242.5 mm250 A
Air-cooled 300 ASingle / dual connector1480 × 400 × 242.5 mm300 A
Air-cooled 400 ASingle / dual connector1480 × 400 × 242.5 mm400 A
Liquid-cooled 600 ASingle / dual connector1630 × 600 × 500 mm600 A
Liquid-cooled 800 ASingle connector1630 × 500 × 370 mm800 A

Terminal current ratings are separate from power-cabinet ratings. Final available power depends on output voltage, cable/connector limits and simultaneous sessions.

Electrical supply

ParameterCatalogue value
Input voltage380 V AC ±15%
Conversion efficiency≥96.5%

Construction and environment

ParameterCatalogue value
Catalogue dimensions (mm)2400 × 2100 × 900
Ingress protectionIP54
Noise≤65 dB

Operation and connectivity

ParameterCatalogue value
Charge modeAutomatic charging to full
AuthenticationRFID card / QR code / password
NetworkEthernet / 4G

Protection

ParameterCatalogue value
Listed functionsConnector temperature monitoring; overvoltage; undervoltage; overload; short circuit; earthing; overtemperature; low temperature; insulation monitoring; reverse polarity; surge protection; emergency stop; leakage protection.

System and terminal arrangement

ParameterCatalogue value
Supported charging connectors2–24
Terminal DC voltage range200–1,000 V
Mingkong charging catalogue · PDF ↗

Drawings & project documents

Request the selected cabinet and terminal dimensions, cable schedule, connection diagram, commissioning requirements and applicable test documents with your enquiry.

Request matching documents ↗
DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

MK DC Split 480–1440 product illustration
MK DC Split 480–1440 · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
DEFINE YOUR CHARGING REQUIREMENT

Request a charging configuration

Price on enquiry

Specify the configuration, quantity and destination. Currency, quotation validity, freight, duties and delivery terms are agreed in the quotation.

Project procurement

New charging sites

Discuss requirements ↗
What to prepare

Site plan, available supply, vehicle types, required charging power and destination.

Distributor procurement

Repeat supply requirements

Discuss requirements ↗
What to prepare

Power variants, connector standards, quantities, branding and documentation needs.

System integrators

Charging-system integration

Discuss requirements ↗
What to prepare

Backend protocol, metering, protection, power allocation and commissioning scope.

Repair & replacement

Existing equipment support

Discuss requirements ↗
What to prepare

Nameplate, controller/module version, fault information, connector details and photos.

Illustrative enquiry scenarios.

Charging selection checklist

  • Destination country, vehicle types and connector standards
  • Required charging power, number of outlets and simultaneous sessions
  • Site AC voltage, frequency, available capacity and installation layout
  • Backend protocol/version, authentication, payment and documentation requirements

Plan your enquiry