Public and commercial parking
For public charging stations, shopping-centre parking and commercial sites. Match the selected power and connector configuration to the available supply and expected vehicle dwell time.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗1,600–3,200 kW flexible DC charging system
1,600–3,200 kW flexible DC charging system. Central power equipment and separate charging terminals for coordinated station deployment.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
1,600–3,200 kW flexible DC charging system from the Mingkong charging equipment range. Power cabinets and dispensing terminals are selected separately. Cabinet power must not be interpreted as the output available at every connector simultaneously.

For public charging stations, shopping-centre parking and commercial sites. Match the selected power and connector configuration to the available supply and expected vehicle dwell time.

For taxi, commuter, logistics and other fleet charging requirements described in the catalogue. Provide the vehicle list, daily charging schedule and number of simultaneous sessions.

Power is pooled in a central cabinet and allocated to dispensing terminals. Select total installed power, terminal current classes and simultaneous charging demand as one system.
The catalogue describes allocation according to vehicle demand and battery status. The detailed control strategy and vehicle communication must be agreed for the project.
A modular architecture is described for staged expansion. Confirm installed modules, expansion headroom, bus capacity and cabinet limits in the offered configuration.
Air-cooled and liquid-cooled terminal alternatives are listed. Their current classes, connector counts, cable system and dimensions must be matched to the power cabinet.

Review site supply, vehicle interfaces, cable reach, mounting and operating-platform requirements together.
Illustrative working sceneChoose a power configuration, then review the matching supply, interfaces and installation requirements.
| Mingkong catalogue reference | Rated power (kW) | Listed output current (A) | Enquiry |
|---|---|---|---|
| MK DC Split 1600–3200 / 1600 kW | 1600 | — | Request this configuration ↗ |
| MK DC Split 1600–3200 / 1800 kW | 1800 | — | Request this configuration ↗ |
| MK DC Split 1600–3200 / 2000 kW | 2000 | — | Request this configuration ↗ |
| MK DC Split 1600–3200 / 2400 kW | 2400 | — | Request this configuration ↗ |
| MK DC Split 1600–3200 / 2560 kW | 2560 | — | Request this configuration ↗ |
| MK DC Split 1600–3200 / 3200 kW | 3200 | — | Request this configuration ↗ |
Mingkong catalogue references identify the configuration for enquiries. Confirm the final ordering code, vehicle interface and technical schedule. Output current, voltage and simultaneous charging limits must be considered together. A dash means no confirmed value is published.
| Terminal class | Connector arrangement | Dimensions | Rated current |
|---|---|---|---|
| Air-cooled 250 A | Single / dual connector | 1480 × 400 × 242.5 mm | 250 A |
| Air-cooled 300 A | Single / dual connector | 1480 × 400 × 242.5 mm | 300 A |
| Air-cooled 400 A | Single / dual connector | Confirm terminal drawing | 400 A |
| Liquid-cooled 600 A | Dual connector | 1630 × 600 × 500 mm | 600 A |
| Liquid-cooled 800 A | Dual connector | 1630 × 600 × 500 mm | 800 A |
Terminal current ratings are separate from power-cabinet ratings. Final available power depends on output voltage, cable/connector limits and simultaneous sessions.
| Parameter | Catalogue value |
|---|---|
| Input voltage | 380 V AC ±15% |
| Conversion efficiency | ≥96.5% |
| Parameter | Catalogue value |
|---|---|
| Catalogue dimensions (mm) | 1460 × 2700 × 1200 |
| Ingress protection | IP54 |
| Noise | ≤65 dB |
| Parameter | Catalogue value |
|---|---|
| Charge mode | Automatic charging to full |
| Authentication | RFID card / QR code / password |
| Network | Ethernet / 4G |
| Parameter | Catalogue value |
|---|---|
| Listed functions | Connector temperature monitoring; overvoltage; undervoltage; overload; short circuit; earthing; overtemperature; low temperature; insulation monitoring; reverse polarity; surge protection; emergency stop; leakage protection. |
| Parameter | Catalogue value |
|---|---|
| Supported charging connectors | 2–32 |
| Terminal DC voltage range | 200–1,000 V |
Request the selected cabinet and terminal dimensions, cable schedule, connection diagram, commissioning requirements and applicable test documents with your enquiry.
Request matching documents ↗
Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Specify the configuration, quantity and destination. Currency, quotation validity, freight, duties and delivery terms are agreed in the quotation.
New charging sites
Discuss requirements ↗Site plan, available supply, vehicle types, required charging power and destination.
Repeat supply requirements
Discuss requirements ↗Power variants, connector standards, quantities, branding and documentation needs.
Charging-system integration
Discuss requirements ↗Backend protocol, metering, protection, power allocation and commissioning scope.
Existing equipment support
Discuss requirements ↗Nameplate, controller/module version, fault information, connector details and photos.
Illustrative enquiry scenarios.

Power options: 7 kW
View specifications ↗
Power options: 20 / 30 / 40 kW
View specifications ↗
Power options: 60 kW
View specifications ↗
Power options: 120 / 160 / 180 / 240 kW
View specifications ↗Use these guides to prepare the information for equipment selection and quotation.