Local distribution upgrades
For replacement or capacity-upgrade enquiries where the existing voltage, connection and physical installation must be retained or deliberately changed.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗Sealed oil-immersed distribution transformer with a dedicated NX1 loss schedule.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
SM-NX1 is a sealed three-phase oil-immersed distribution transformer with a dedicated NX1 performance schedule. It is selected around the actual distribution voltage, load capacity and winding connection. The table distinguishes Dy and Yy load-loss entries where applicable, so the connection group belongs in the initial enquiry.

For replacement or capacity-upgrade enquiries where the existing voltage, connection and physical installation must be retained or deliberately changed.

For industrial and local distribution projects requiring an oil-immersed transformer and a defined loss schedule.

The M designation identifies sealed construction. Tank arrangement, cooling surfaces, fittings and accessories should be reviewed on the selected rating’s drawing.
The design focuses on the core and winding arrangement associated with the NX1 loss schedule. The actual no-load and load-loss values are provided for each listed capacity.
The table separates Dy and Yy values at relevant ratings. State the required group when comparing offers, together with the loss reference temperature.
The displayed entries use 4% impedance through 500 kVA and 4.5% from 630 to 1,600 kVA. Select the complete rating combination for the distribution system.

Match the selected transformer to the room layout, terminal arrangement, cooling clearances and approved drawings.
Factory preparation photograph · reference assemblyCompare the capacity and impedance together. You can start an enquiry from a specific row. On a small screen, scroll the table sideways.
| Capacity (kVA) | No-load current (%) | Load loss Dy (W) | Load loss Yy (W) | No-load loss (W) | Short-circuit impedance (%) | Enquiry |
|---|---|---|---|---|---|---|
| 30 | 1.5 | 505 | 480 | 80 | 4.0 | Request this rating ↗ |
| 50 | 1.3 | 730 | 695 | 100 | 4.0 | Request this rating ↗ |
| 63 | 1.2 | 870 | 830 | 110 | 4.0 | Request this rating ↗ |
| 80 | 1.2 | 1050 | 1000 | 130 | 4.0 | Request this rating ↗ |
| 100 | 1.1 | 1265 | 1200 | 150 | 4.0 | Request this rating ↗ |
| 125 | 1.1 | 1510 | 1440 | 170 | 4.0 | Request this rating ↗ |
| 160 | 1.0 | 1850 | 1760 | 200 | 4.0 | Request this rating ↗ |
| 200 | 1.0 | 2185 | 2080 | 240 | 4.0 | Request this rating ↗ |
| 250 | 0.9 | 2560 | 2440 | 290 | 4.0 | Request this rating ↗ |
| 315 | 0.9 | 3065 | 2920 | 340 | 4.0 | Request this rating ↗ |
| 400 | 0.8 | 3615 | 3440 | 410 | 4.0 | Request this rating ↗ |
| 500 | 0.8 | 4330 | 4120 | 480 | 4.0 | Request this rating ↗ |
| 630 | 0.6 | 4960 | 4960 | 570 | 4.5 | Request this rating ↗ |
| 800 | 0.6 | 6000 | 6000 | 700 | 4.5 | Request this rating ↗ |
| 1000 | 0.6 | 8240 | 8240 | 830 | 4.5 | Request this rating ↗ |
| 1250 | 0.5 | 9600 | 9600 | 970 | 4.5 | Request this rating ↗ |
| 1600 | 0.5 | 11600 | 11600 | 1170 | 4.5 | Request this rating ↗ |
Checked against the original transformer catalogue, PDF page 17, printed page 23. HV options: 10 / 6.3 / 6 kV; taps: ±5% or ±2 × 2.5%; LV: 0.4 kV; vector groups: Yyn0 / Dyn11. Catalogue efficiency designation is not a destination-market certification.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Send the load schedule, HV/LV voltages, kVA and site conditions. Identify loss limits, vector group and required tests.
Model lists & repeat orders
Discuss supply requirements ↗List preferred kVA and voltage combinations, destination requirements, quantities and spare-parts or documentation needs.
Equipment integration & matching
Discuss an assembly ↗Provide the substation or equipment layout, terminal positions, cooling arrangement and monitoring interfaces.
Identify an existing unit or part
Identify a replacement ↗Send the nameplate, existing dimensions, cable or busbar interfaces and the reason for replacement.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Catalogue capacity: 30–1,600 kVA
View specifications ↗
S13 table HV options: 20 / 22 / 24 kV
View specifications ↗
Voltage class: 35 kV
View specifications ↗
Voltage class: 35 kV
View specifications ↗Mingkong Transformer Selection Guide · Updated 24 October 2026 · Chinese / English
For a quotation, include your required model, rating, quantity and operating conditions.
Use these guides to prepare the information for equipment selection and quotation.