Skip to content
TRANSFORMERS & ELECTRICAL COMPONENTS
Prefabricated Substations

YB□-12/0.4 · Prefabricated substation

Prefabricated substation combining HV switching, a transformer and LV distribution. Define the assembly around your single-line diagram, feeder schedule and site layout.

Model voltage designation
12 / 0.4 kV
Arrangement
European type
Enquire about YB□-12/0.4 ↗

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where YB□-12/0.4 fits

YB prefabricated substations combine high-voltage switching, a transformer and low-voltage distribution in an integrated assembly. The arrangement is used for building, industrial and temporary supply projects. Each section is selected around the single-line diagram so transformer duty, feeder protection and the enclosure layout work together.

Illustrative building distribution setting
Application illustration
APPLICATION / 01

Residential and commercial developments

For neighbourhoods, hotels, shopping facilities and high-rise projects requiring a packaged HV/LV supply arrangement.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 02

Industrial and infrastructure sites

For factories, airports, railways, ports and temporary installations where equipment scope and site interfaces can be defined together.

PRODUCT ENGINEERING

Construction & operating functions

YB□-12/0.4 product illustration
YB□-12/0.4Product illustration · Configuration varies by specification
DETAIL / 01

Three coordinated equipment sections

High-voltage switching, transformer and low-voltage distribution are arranged as a coordinated package. The selected equipment determines the overall footprint and compartment layout.

DETAIL / 02

High-voltage switching choice

The technical information covers load-switch arrangements, including vacuum-switch options. Switch duty and transformer protection must be selected for the actual incoming circuit.

DETAIL / 03

Transformer integration

The capacity and voltage combination determine the transformer selection. Terminal positions, cooling and access requirements need to match the surrounding assembly.

DETAIL / 04

Low-voltage distribution scope

Define the main LV switching and each outgoing feeder from the project load schedule. Metering, compensation and control requirements should be included explicitly where required.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

SPECIFICATION & INTEGRATIONReview equipment installation

Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.

Illustrative working scene
Single-line diagram
Identify incoming circuits, transformer capacity and outgoing feeder ratings.
Protection and metering
Specify the metering location, protection arrangement and any auxiliary supply/control requirements.
Installation environment
The stated normal range is −25 to +40 °C with altitude up to 2,000 m; special conditions require a specified design.

Installation & connection checklist

  • Provide foundation dimensions, cable trench/duct positions and entry directions.
  • Identify access-door clearance, ventilation and equipment-removal space.
  • State the delivery and unloading arrangement for the assembled equipment.
  • Agree the single-line, layout and wiring drawings before order release.

Drawings & configuration documents

Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

YB□-12/0.4 product illustration
YB□-12/0.4 · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the single-line diagram, transformer duty, feeder schedule and site plan.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

Identify recurring electrical schemes, destination conditions and the required equipment scope.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Provide civil, cable, ventilation and control interfaces for the complete substation arrangement.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Send the existing layout, nameplates and available access; identify which sections will be retained.

Illustrative enquiry scenarios.

Selection checklist for YB□-12/0.4
  • Single-line diagram and incoming network arrangement
  • Transformer rating, outgoing feeder schedule and metering scheme
  • Site dimensions, cable entry, access, ventilation and drainage
  • Protection, control supply, communication and delivery scope
  • Provide foundation dimensions, cable trench/duct positions and entry directions.
  • Identify access-door clearance, ventilation and equipment-removal space.
  • State the delivery and unloading arrangement for the assembled equipment.
  • Agree the single-line, layout and wiring drawings before order release.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Product catalogue

Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English

Download PDF ↗

For a quotation, include your required model, rating, quantity and operating conditions.