Power and industrial substations
For receiving and distributing power with switching, protection and monitoring functions.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗Indoor withdrawable metal-clad switchgear for 24 kV-class applications.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
KYN28A-24 is indoor metal-clad withdrawable switchgear for 24 kV three-phase systems. It combines a withdrawable vacuum-breaker arrangement with primary-circuit insulation and secondary protection/control equipment. The configuration is defined by feeder duty, current, fault level and the required control scheme.

For receiving and distributing power with switching, protection and monitoring functions.

For high-rise and large-building installations using a 24 kV distribution arrangement.

The breaker arrangement is selected together with its truck and cabinet interface. This is especially important when specifying replacements or matching an existing lineup.
Bus insulation uses heat-shrink or epoxy-coated arrangements described for the series. The selected insulation and breaker configuration form part of the complete assembly.
Interlocking functions address truck movement, earthing and compartment access. The actual combination must match the selected primary and secondary scheme.
Secondary control and protection components are configured around the feeder duty. Supply the required protection functions, CT/PT information and control voltage.
The table gives two cabinet-width alternatives with corresponding dimensions. Select the physical arrangement together with current rating, cable terminations and installation access.
Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.
Illustrative working sceneState any different ambient temperature, altitude, humidity, dust, salt or corrosive exposure when requesting the installation-specific configuration.
Review the listed configuration and applicable units. On a small screen, scroll the table sideways.
| Parameter | Catalogue value |
|---|---|
| Rated voltage | 24 kV |
| Frequency | 50 / 60 Hz |
| Rated current options | 630 / 1,250 / 1,600 / 2,000 / 2,500 / 3,150 A |
| Short-circuit breaking current options | 20 / 31.5 kA |
| Short-time withstand current (4 s) | 20 / 31.5 kA |
| Peak withstand current options | 50 / 80 kA |
| Auxiliary control voltage | DC or AC 110 / 220 V |
| Auxiliary-circuit power-frequency withstand | 2,000 V |
| Enclosure protection | IP4X; IP2X with breaker-compartment door open |
| Cabinet dimensions (W × D × H) | 800 × 1,810 × 2,380 or 1,000 × 1,810 × 2,380 mm |
| Catalogue weight range | 840–1,440 kg |
Checked against original distribution catalogue PDF page 14. 20 kA and 31.5 kA variants correspond to 50 kA and 80 kA peak ratings respectively. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.
Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Provide voltage, fault duty, circuit schedule and required protection scheme.
Model lists & repeat orders
Discuss supply requirements ↗List circuit configurations, ratings, preferred components and destination documentation needs.
Equipment integration & matching
Discuss an assembly ↗Send the line-up layout, bus interfaces, breaker specification and secondary wiring requirements.
Identify an existing unit or part
Identify a replacement ↗Provide the existing panel and breaker details, dimensions, plug connections and interlocks.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Voltage designation: 40.5 kV
View specifications ↗
Voltage designation: 40.5 kV
View specifications ↗
Voltage designation: 3.6 / 7.2 / 12 kV
View specifications ↗
Voltage designation: 12 / 24 kV
View specifications ↗Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English
For a quotation, include your required model, rating, quantity and operating conditions.