Substation incoming and outgoing circuits
For power receiving and feeder distribution with a defined bus arrangement and protection scheme.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗Indoor metal-clad withdrawable switchgear for 12 kV-class distribution.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
KYN28A-12 is indoor metal-clad withdrawable switchgear for distribution, protection and monitoring. The compartmented design separates busbars, breaker truck, cables and secondary instruments. Main-circuit rating and the actual load-switching duty are selected together.

For power receiving and feeder distribution with a defined bus arrangement and protection scheme.

For plant circuits where the load type and switching frequency form part of the selection, including motor duties requiring a specific review.

The arrangement separates the busbar, breaker-truck, cable and relay/instrument sections. This organisation helps identify the space and interfaces required for each part of the feeder.
The breaker truck, shutter and secondary-plug arrangement are part of the withdrawable design. Matching these interfaces is essential for a replacement truck or breaker enquiry.
The construction drawing includes the earthing switch, cable terminations, current transformers and surge-protection location. The actual equipment list depends on the selected circuit.
Pressure-relief and heating provisions are shown in the design. Room layout and auxiliary-supply requirements should accommodate the selected arrangement.
Motor and capacitor switching are duty-specific applications. Provide the load characteristics and required operating duty so the appropriate breaker and protective arrangement can be reviewed.
Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.
Illustrative working sceneState any different ambient temperature, altitude, humidity, dust, salt or corrosive exposure when requesting the installation-specific configuration.
Review the listed configuration and applicable units. On a small screen, scroll the table sideways.
| Parameter | Catalogue value |
|---|---|
| Rated voltage options | 3.6 / 7.2 / 12 kV |
| Rated frequency | 50 Hz |
| Breaker and cabinet current options | 630 / 1,250 / 1,600 / 2,000 / 2,500 / 3,150 A |
| Short-circuit breaking current options | 16 / 20 / 25 / 31.5 / 40 / 50 kA |
| Short-time withstand (4 s) options | 16 / 20 / 25 / 31.5 / 40 / 50 kA |
| Peak withstand/making current options | 40 / 50 / 63 / 80 / 100 / 125 kA |
| 1 min power-frequency withstand by voltage class | 24 / 32 / 42 kV |
| Lightning impulse withstand by voltage class | 40 / 60 / 75 kV |
| Enclosure protection | IP4X; IP2X at compartments with the breaker door open |
Checked against original distribution catalogue PDF page 15. Insulation values correspond respectively to 3.6, 7.2 and 12 kV classes; select one complete rating combination. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.
Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Provide voltage, fault duty, circuit schedule and required protection scheme.
Model lists & repeat orders
Discuss supply requirements ↗List circuit configurations, ratings, preferred components and destination documentation needs.
Equipment integration & matching
Discuss an assembly ↗Send the line-up layout, bus interfaces, breaker specification and secondary wiring requirements.
Identify an existing unit or part
Identify a replacement ↗Provide the existing panel and breaker details, dimensions, plug connections and interlocks.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Voltage designation: 40.5 kV
View specifications ↗
Voltage designation: 40.5 kV
View specifications ↗
Voltage designation: 24 kV
View specifications ↗
Voltage designation: 12 / 24 kV
View specifications ↗Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English