GZDW · DC power supply system

DC supply cabinet for substation control, protection and emergency electrical loads.

DC output options
220 / 110 / 48 V
Functions
Charging, monitoring and DC distribution
Enquire about GZDW ↗

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where GZDW fits

GZDW supplies DC power for substation protection, breaker operation, automation and emergency loads. The system combines charging, batteries, distribution and monitoring so the DC duty can be defined for both normal operation and loss of the AC supply. Battery capacity is selected from the load profile and required autonomy.

GZDW product illustration
Product illustration
APPLICATION / 01

Substation operating power

For relay protection, trip and close circuits and associated control equipment.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 02

Essential DC loads

For emergency and automation loads that need a defined supply duration following AC supply loss.

PRODUCT ENGINEERING

Construction & operating functions

GZDW product illustration
GZDWProduct illustration · Configuration varies by specification
DETAIL / 01

Charger and battery system

The charging equipment and battery bank operate as a coordinated DC source. Battery chemistry, capacity and charging requirements must be agreed together.

DETAIL / 02

Charging modes

Equalising and float charging modes are described, together with voltage and current limiting functions. The selected charging programme must match the battery specification.

DETAIL / 03

System monitoring

The monitoring arrangement covers charging and bus quantities and can include individual battery-voltage information. The required alarm points and displayed measurements belong in the specification.

DETAIL / 04

DC distribution

Outgoing circuits supply the selected operating and auxiliary loads. Continuous load, short-duration operating demand and protective-device coordination all affect the distribution design.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

SPECIFICATION & INTEGRATIONReview equipment installation

Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.

Illustrative working scene
DC duty
Provide DC voltage, continuous loads, breaker operating demand and required backup duration.
Battery scope
State preferred battery chemistry, installation space and maintenance requirements.
Monitoring
Identify alarm contacts, communication protocol and required local display language.

Installation & connection checklist

  • Provide the AC input supply arrangement.
  • Submit the DC load schedule and trip/close duty.
  • Coordinate battery and charger cabinet space and ventilation with the installation.
  • Agree battery calculations, circuit diagrams and delivery-test documents.
RATING DATA

Technical parameters

6Parameter / configuration entries
Units shownCompare values with their units
Selected variantConfirm the matching configuration

Review the listed configuration and applicable units. On a small screen, scroll the table sideways.

ParameterCatalogue value
AC inputAC 380 V ±10%
DC outputDC 220 / 110 / 48 V
Output current options10 / 20 / 30 / 40 / 50 / 60 / 100 / 200 A
Noise≤55 dB
Main temperature rise≤60°C
DutyContinuous

Checked against original PDF page 39 of the distribution equipment guide. Select the DC voltage and current together. Regulation accuracy and ripple requirements are to be agreed in the technical schedule.

Drawings & configuration documents

Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

GZDW product illustration
GZDW · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the protection scheme or DC load schedule, auxiliary supply and required functions.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

List exact device variants, input ratings, interfaces, language and documentation requirements.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Provide secondary schematics, I/O allocation, terminal arrangements and panel dimensions.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Start with the device nameplate, wiring drawing and settings or battery data relevant to the replacement.

Illustrative enquiry scenarios.

Selection checklist for GZDW
  • Equipment being protected or supplied and the required functions
  • AC/DC supply, load duty and CT/PT input information as applicable
  • I/O list, trip/close circuits and communication protocol
  • Panel dimensions, interface language and required technical documents
  • Provide the AC input supply arrangement.
  • Submit the DC load schedule and trip/close duty.
  • Coordinate battery and charger cabinet space and ventilation with the installation.
  • Agree battery calculations, circuit diagrams and delivery-test documents.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.