Low-voltage Distribution

GGD · Low-voltage distribution cabinet

Fixed low-voltage distribution cabinet for power, lighting and auxiliary distribution.

Catalogue designation
380 V
Selection
Circuit schedule and enclosure arrangement
Enquire about GGD ↗

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where GGD fits

GGD is fixed-type low-voltage switchgear for power and lighting distribution. Switching and protective devices are mounted in a cabinet arrangement selected around the feeder schedule. It is suited to projects that require fixed circuits with clearly defined access, connections and maintenance provisions.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 01

Plant distribution boards

For incoming and outgoing circuits supplying industrial power and service loads.

Illustrative building distribution setting
Application illustration
APPLICATION / 02

Building power and lighting

For distribution rooms using fixed switching assemblies and coordinated outgoing protection.

PRODUCT ENGINEERING

Construction & operating functions

GGD product illustration
GGDProduct illustration · Configuration varies by specification
DETAIL / 01

Cold-formed steel framework

The cabinet uses an 8MF cold-formed steel structure with partly welded assembly. Modular mounting positions support the internal electrical layout.

DETAIL / 02

Fixed circuit construction

Power circuits and installed switching devices remain fixed in their mounting arrangement. Equipment access and isolation requirements should therefore be planned with the switchroom design.

DETAIL / 03

Removable access components

Removable doors and top covers assist assembly and access to the busbar area. Door grounding connections form part of the cabinet arrangement.

DETAIL / 04

Compensation coordination

Where reactive-power compensation is required, identify the associated compensation section in the line-up and coordinate its bus connection and protective devices.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

SPECIFICATION & INTEGRATIONReview equipment installation

Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.

Illustrative working scene
Electrical duty
Provide the circuit schedule, bus rating and required fault withstand.
Devices and metering
Specify switching devices, trip functions, metering and outgoing protection.
Enclosure requirements
Define access, cable entry, finish and the required enclosure protection for the site.

Installation & connection checklist

  • Confirm cabinet dimensions and line-up connection positions.
  • Provide cable or busduct termination drawings.
  • State required access and isolation arrangements for maintenance.
  • Agree the actual configured rating rather than assuming one maximum applies to every GGD variant.
Operating conditions for the listed configuration
  • Indoor installation; altitude up to 2,000 m.
  • Ambient −5 to +40 °C; 24-hour average up to +35 °C.
  • Relative humidity up to 50% at +40 °C; higher humidity at lower temperatures requires consideration of condensation.

State any different ambient temperature, altitude, humidity, dust, salt or corrosive exposure when requesting the installation-specific configuration.

RATING DATA

Technical parameters

8Parameter / configuration entries
Units shownCompare values with their units
Selected variantConfirm the matching configuration

Review the listed configuration and applicable units. On a small screen, scroll the table sideways.

SeriesVariantVoltage (V)Rated current (A)Breaking current (kA)1 s withstand (kA)Peak withstand (kA)
GGD1A3801000151530
GGD1B380600 (630)151530
GGD1C380400151530
GGD2A3801500 (1600)303063
GGD2B3801000303063
GGD2C380600303063
GGD3B38025005050105
GGD3C38020005050105

Checked against original distribution catalogue PDF page 33. Only the listed variants are shown. Other ratings require a confirmed technical schedule. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.

Drawings & configuration documents

Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

GGD product illustration
GGD · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the load list, single-line diagram, fault duty and switchroom layout.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

Identify recurring cabinet arrangements, circuit quantities and preferred installed devices.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Supply the feeder schedule, wiring diagrams, mounting details and cable-entry requirements.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Provide cabinet, drawer or device identification, dimensions and connection details for the part to be replaced.

Illustrative enquiry scenarios.

Selection checklist for GGD
  • Single-line diagram, load list and outgoing circuit schedule
  • System voltage, bus current and short-circuit duty
  • Fixed or withdrawable units, protection and control functions
  • Enclosure dimensions, mounting, cable entry and site conditions
  • Confirm cabinet dimensions and line-up connection positions.
  • Provide cable or busduct termination drawings.
  • State required access and isolation arrangements for maintenance.
  • Agree the actual configured rating rather than assuming one maximum applies to every GGD variant.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Product catalogue

Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English

Download PDF ↗

For a quotation, include your required model, rating, quantity and operating conditions.