Skip to content
TRANSFORMERS & ELECTRICAL COMPONENTS
Low-voltage Distribution

PZ30 · Distribution board

Modular terminal distribution box for building and small industrial circuits.

Catalogue designation
Terminal distribution
Selection
Circuit schedule and enclosure arrangement
Enquire about PZ30 ↗

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where PZ30 fits

PZ30 is a modular terminal-distribution box for building and local service circuits. DIN-rail mounted devices provide the selected protection and switching functions, while the enclosure organises circuit access and wiring. The required circuit count and device widths determine the box size.

Illustrative building distribution setting
Application illustration
APPLICATION / 01

Building final circuits

For residential, commercial and service-area lighting or small-power circuits.

Illustrative industrial infrastructure setting
Application illustration
APPLICATION / 02

Local auxiliary distribution

For terminal circuits in industrial and infrastructure buildings where modular devices are appropriate.

PRODUCT ENGINEERING

Construction & operating functions

PZ30 product illustration
PZ30Product illustration · Configuration varies by specification
DETAIL / 01

Modular device mounting

The internal rail arrangement accommodates modular protective and switching devices. Rail space must be checked against the actual device widths and required spare ways.

DETAIL / 02

Covered live parts

Operating handles are accessible through the front arrangement while internal wiring and live parts remain behind the cover. The chosen cover and door arrangement must match the enclosure variant.

DETAIL / 03

Surface and recessed options

The series includes different mounting arrangements. Recessed installations require coordination of the wall opening and finished surface depth.

DETAIL / 04

Device-dependent protection

Overload, short-circuit, residual-current or overvoltage protection comes from the installed devices. The enclosure model alone does not define those functions.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

SPECIFICATION & INTEGRATIONReview equipment installation

Match the installation drawing, cable routes, clearances and electrical duty for the selected equipment.

Illustrative working scene
Circuit schedule
List outgoing circuits, protective-device poles and any auxiliary modules.
Box size
Select enclosure space from actual device widths, wiring space and spare capacity.
Mounting
State surface or recessed installation and cable-entry directions.

Installation & connection checklist

  • Check the mounting variant before using the dimension table.
  • Provide neutral and protective-earth connection requirements.
  • Identify door-opening constraints and available wall space.
  • Confirm the installed component list with the final circuit diagram.
RATING DATA

PZ30-B surface-mounted enclosure dimensions

13Parameter / configuration entries
Units shownCompare values with their units
Selected variantConfirm the matching configuration

Review the listed configuration and applicable units. On a small screen, scroll the table sideways.

Specification codeHeight (mm)Width (mm)Depth (mm)
6#23020090
8#23024090
10#28028090
12#28031090
15#28037090
18#28042090
20#28046090
24#47031090
30#47037090
36#47042090
40#47046090
45#63037090
54#63042090

Checked against original distribution catalogue PDF page 38. PZ30-B surface-mounted large enclosure dimensions only. Recessed installation dimensions require a separate drawing. Ratings describe catalogue options, not every possible combination; select the complete configuration in the technical schedule.

Drawings & configuration documents

Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

PZ30 product illustration
PZ30 · Product illustration

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the load list, single-line diagram, fault duty and switchroom layout.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

Identify recurring cabinet arrangements, circuit quantities and preferred installed devices.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Supply the feeder schedule, wiring diagrams, mounting details and cable-entry requirements.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Provide cabinet, drawer or device identification, dimensions and connection details for the part to be replaced.

Illustrative enquiry scenarios.

Selection checklist for PZ30
  • Single-line diagram, load list and outgoing circuit schedule
  • System voltage, bus current and short-circuit duty
  • Fixed or withdrawable units, protection and control functions
  • Enclosure dimensions, mounting, cable entry and site conditions
  • Check the mounting variant before using the dimension table.
  • Provide neutral and protective-earth connection requirements.
  • Identify door-opening constraints and available wall space.
  • Confirm the installed component list with the final circuit diagram.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Product catalogue

Mingkong High & Low Voltage Switchgear Selection Guide · Updated 24 October 2026 · Chinese / English

Download PDF ↗

For a quotation, include your required model, rating, quantity and operating conditions.