
Public and commercial buildings
For hospitals, hotels, theatres, shopping facilities and residential load centres. Review ventilation, access and the project’s acoustic requirements.
Four product ranges · Manufacturing and coordinated supply

Product illustration. Actual configuration varies by specification.
Open product image ↗Cast-resin dry-type transformer for electrical load centres in buildings and infrastructure.
Price on enquiry · Configuration, quantity & destination
Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.
SC(B)12 is a three-phase epoxy-resin cast transformer for building and infrastructure distribution. Its winding insulation and reinforced cast structure are combined with capacity-specific electrical data. Procurement should identify the required voltage combination, vector group, impedance and installation arrangement in addition to the SC(B)12 series name.

For hospitals, hotels, theatres, shopping facilities and residential load centres. Review ventilation, access and the project’s acoustic requirements.

For stations, airports, tunnels and combined substations. The equipment layout should allow access to terminals and specified monitoring accessories.

The winding insulation uses an epoxy-resin casting process. Resin mixing and vacuum degassing prepare the mixture before casting, helping the insulation surround the winding and fill the spaces within the assembly.
Reinforcing insulation materials are incorporated within the cast winding structure. The filled resin and reinforcement form a coordinated mechanical assembly around the winding; required short-circuit and insulation test documents should be specified for the selected design.
A foil-type low-voltage winding is an option identified in the series designation. Confirm the actual winding construction with the selected capacity, voltage combination and technical schedule.
The 30–2,500 kVA table identifies current and loss values for each rating. At 630 kVA, two impedance arrangements are listed; larger entries use the corresponding 6% configuration.
This page covers the conventional SC(B)12 series. The three-dimensional wound-core version has a separate product page and performance table, so the core construction should be stated in quotations and repeat orders.

Match the selected transformer to the room layout, terminal arrangement, cooling clearances and approved drawings.
Factory preparation photograph · reference assemblyCompare the capacity and impedance together. You can start an enquiry from a specific row. On a small screen, scroll the table sideways.
| Capacity (kVA) | No-load current (%) | Load loss (W) | No-load loss (W) | Short-circuit impedance (%) | Enquiry |
|---|---|---|---|---|---|
| 30 | 2.00 | 710 | 150 | 4.0 | Request this rating ↗ |
| 50 | 2.00 | 1000 | 215 | 4.0 | Request this rating ↗ |
| 80 | 1.50 | 1380 | 295 | 4.0 | Request this rating ↗ |
| 100 | 1.50 | 1570 | 320 | 4.0 | Request this rating ↗ |
| 125 | 1.30 | 1850 | 375 | 4.0 | Request this rating ↗ |
| 160 | 1.30 | 2130 | 430 | 4.0 | Request this rating ↗ |
| 200 | 1.10 | 2530 | 495 | 4.0 | Request this rating ↗ |
| 250 | 1.10 | 2760 | 575 | 4.0 | Request this rating ↗ |
| 315 | 1.00 | 3470 | 705 | 4.0 | Request this rating ↗ |
| 400 | 1.00 | 3990 | 785 | 4.0 | Request this rating ↗ |
| 500 | 1.00 | 4880 | 930 | 4.0 | Request this rating ↗ |
| 630 | 0.85 | 5880 | 1070 | 4.0 | Request this rating ↗ |
| 630 | 0.85 | 5960 | 1040 | 6.0 | Request this rating ↗ |
| 800 | 0.85 | 6960 | 1210 | 6.0 | Request this rating ↗ |
| 1000 | 0.85 | 8130 | 1410 | 6.0 | Request this rating ↗ |
| 1250 | 0.85 | 9690 | 1670 | 6.0 | Request this rating ↗ |
| 1600 | 0.85 | 11700 | 1960 | 6.0 | Request this rating ↗ |
| 2000 | 0.70 | 14440 | 2440 | 6.0 | Request this rating ↗ |
| 2500 | 0.70 | 17170 | 2880 | 6.0 | Request this rating ↗ |
10 kV-class catalogue table, checked against original PDF page 10. HV options: 10 / 6.3 / 6 kV; LV: 0.4 kV; vector groups: Dyn11 / Yyn0. Select the impedance and tapping arrangement together with the capacity. Loss-reference temperature and the final technical schedule are to be agreed.
Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.
Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.
For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.
Contact about this model ↗Choose your enquiry type. Start with the information you have.
Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.
New installations & project tenders
Discuss a project ↗Send the load schedule, HV/LV voltages, kVA and site conditions. Identify loss limits, vector group and required tests.
Model lists & repeat orders
Discuss supply requirements ↗List preferred kVA and voltage combinations, destination requirements, quantities and spare-parts or documentation needs.
Equipment integration & matching
Discuss an assembly ↗Provide the substation or equipment layout, terminal positions, cooling arrangement and monitoring interfaces.
Identify an existing unit or part
Identify a replacement ↗Send the nameplate, existing dimensions, cable or busbar interfaces and the reason for replacement.
Illustrative enquiry scenarios.
Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Construction: Epoxy resin cast
View specifications ↗
Construction: Epoxy resin cast
View specifications ↗
Voltage classes: 10 / 20 / 35 kV
View specifications ↗
Core: Three-dimensional wound core
View specifications ↗Mingkong Transformer Selection Guide · Updated 24 October 2026 · Chinese / English
For a quotation, include your required model, rating, quantity and operating conditions.
Use these guides to prepare the information for equipment selection and quotation.