Transformers

SC(B)-NX1 · Cast-resin dry-type transformer

Cast-resin dry-type transformer with catalogue ratings from 30 to 2,500 kVA for building and infrastructure distribution. Select the voltage combination, impedance and loss limits for your project.

Brand
Mingkong
Model
SC(B)-NX1
Supply
Factory supply
Construction
Epoxy resin cast
Catalogue capacity
30–2,500 kVA
LV rating
0.4 kV
Vector groups
Dyn11 / Yyn0
Enquire about SC(B)-NX1 ↗

Price on enquiry · Configuration, quantity & destination

Supply scope, manufacturer information, applicable documents and warranty arrangements are confirmed in the quotation and order.

APPLICATION & DUTY

Where SC(B)-NX1 fits

SC(B)-NX1 is a three-phase cast-resin transformer for distributing power close to building and infrastructure loads. Selection combines the required capacity with the primary and secondary voltages, winding connection, impedance and loss limits. The NX1 designation identifies this performance series; the actual operating requirement is defined by the selected rating.

Illustrative building distribution setting
Application illustration
APPLICATION / 01

Commercial and public buildings

For transformer rooms serving offices, hospitals, hotels and commercial centres. Include the room layout, ventilation arrangement and building noise requirements in the specification.

Illustrative transport infrastructure setting
Application illustration
APPLICATION / 02

Transport and urban infrastructure

For stations, airports, tunnels and combined substations. Review equipment access, connection direction and maintenance space alongside the electrical rating.

PRODUCT ENGINEERING

Construction & operating functions

SC(B)-NX1 product illustration
SC(B)-NX1Product illustration · Configuration varies by specification
DETAIL / 01

Cast-resin winding insulation

The winding insulation uses an epoxy-resin casting process. Resin mixing and vacuum degassing prepare the mixture before casting, helping the insulation surround the winding and fill the spaces within the assembly.

DETAIL / 02

Reinforced winding construction

Reinforcing insulation materials are incorporated within the cast winding structure. The filled resin and reinforcement form a coordinated mechanical assembly around the winding; required short-circuit and insulation test documents should be specified for the selected design.

DETAIL / 03

Low-voltage winding selection

A foil-type low-voltage winding is an option identified in the series designation. Confirm the actual winding construction with the selected capacity, voltage combination and technical schedule.

DETAIL / 04

Rating-specific loss selection

The table covers 30–2,500 kVA and separates no-load loss, load loss and no-load current. Comparing these quantities at the same capacity and impedance helps purchasers define a consistent technical basis for quotations.

DETAIL / 05

Capacity and impedance together

The 630 kVA entries have different impedance and loss combinations. Identify the required row when enquiring, rather than specifying capacity alone; the surrounding distribution design determines the appropriate impedance.

DEFINE THE SELECTED ASSEMBLY

Configuration & installation interfaces

Transformer assembly and cooling equipment during factory preparation
SPECIFICATION & INTEGRATIONReview transformer installation

Match the selected transformer to the room layout, terminal arrangement, cooling clearances and approved drawings.

Factory preparation photograph · reference assembly
Primary and secondary
Listed HV options are 10, 6.3 and 6 kV with 0.4 kV LV. State the actual network voltage and any different secondary requirement.
Winding connection
Dyn11 and Yyn0 are listed alternatives. Provide the required connection group and any parallel-operation requirement.
Loss specification
Send the destination-market loss requirement and reference temperature. Include any requested noise or partial-discharge acceptance limits for agreement.

Installation & connection checklist

  • State cable or busbar connections and their entry direction.
  • Provide transformer-room dimensions, access openings and lifting restrictions.
  • Identify enclosure, temperature indication, alarm/trip contacts and cooling requirements.
  • For replacement, include the nameplate, terminal photographs and existing mounting dimensions.
RATING DATA

Technical parameters

30–2,500 kVACapacity entries in this table
19Listed rating configurations
4.0 / 6.0%Impedance options · see matching row

Compare the capacity and impedance together. You can start an enquiry from a specific row. On a small screen, scroll the table sideways.

Capacity (kVA)No-load current (%)Load loss (W)No-load loss (W)Short-circuit impedance (%)Enquiry
302.006401354.0Request this rating ↗
502.009001954.0Request this rating ↗
801.5012402654.0Request this rating ↗
1001.5014152904.0Request this rating ↗
1251.3016653404.0Request this rating ↗
1601.3019153854.0Request this rating ↗
2001.1022754454.0Request this rating ↗
2501.1024855154.0Request this rating ↗
3151.0031256354.0Request this rating ↗
4001.0035907054.0Request this rating ↗
5001.0043908354.0Request this rating ↗
6300.8552909654.0Request this rating ↗
6300.8553659356.0Request this rating ↗
8000.85626510956.0Request this rating ↗
10000.85731512756.0Request this rating ↗
12500.85872015056.0Request this rating ↗
16000.851055517656.0Request this rating ↗
20000.701300521956.0Request this rating ↗
25000.701545525906.0Request this rating ↗

10 kV-class catalogue table, checked against original PDF page 6. HV options: 10 / 6.3 / 6 kV; LV: 0.4 kV; vector groups: Dyn11 / Yyn0. Select the impedance and tapping arrangement together with the capacity. Loss-reference temperature and the final technical schedule are to be agreed.

Drawings & configuration documents

Send your selected rating and installation requirements to request the matching dimensional drawing, connection details and technical schedule.

DOCUMENTS · DELIVERY · SUPPORT

Technical coordination & after-sales enquiries

Transformers in the production workshop
Transformer workshop

Confirm the order documents

Agree the selected specifications, applicable drawings, inspection records and identification requirements in the quotation and order.

Coordinate delivery

Include quantity, destination, packing requirements and preferred trade terms. Confirm transport scope and the requested delivery schedule with the quotation.

Request technical support

For an existing unit, provide its model, nameplate or order reference and a description of the issue. Include relevant photos or records already available. Warranty and service scope follow the agreed order terms.

Contact about this model ↗
START WITH WHAT YOU HAVE

Prepare a quotation for this equipment.

Choose your enquiry type. Start with the information you have.

Price on enquiry

Quotations are prepared for the selected configuration, quantity and destination. Currency, validity, delivery terms, freight and any applicable duties or taxes are specified in the quotation.

Project procurement

New installations & project tenders

Discuss a project ↗
What to prepare

Send the load schedule, HV/LV voltages, kVA and site conditions. Identify loss limits, vector group and required tests.

Distributor procurement

Model lists & repeat orders

Discuss supply requirements ↗
What to prepare

List preferred kVA and voltage combinations, destination requirements, quantities and spare-parts or documentation needs.

Panel & equipment builders

Equipment integration & matching

Discuss an assembly ↗
What to prepare

Provide the substation or equipment layout, terminal positions, cooling arrangement and monitoring interfaces.

Repair & replacement

Identify an existing unit or part

Identify a replacement ↗
What to prepare

Send the nameplate, existing dimensions, cable or busbar interfaces and the reason for replacement.

Illustrative enquiry scenarios.

Selection checklist for SC(B)-NX1
  • Required kVA, HV/LV voltages, frequency and vector group
  • Tapping arrangement, impedance and required loss limits
  • Indoor/outdoor site, ambient temperature, altitude and ventilation
  • Cable or busbar connections, installation dimensions, monitoring and test documents
  • State cable or busbar connections and their entry direction.
  • Provide transformer-room dimensions, access openings and lifting restrictions.
  • Identify enclosure, temperature indication, alarm/trip contacts and cooling requirements.
  • For replacement, include the nameplate, terminal photographs and existing mounting dimensions.

From enquiry to an agreed supply

  1. Share the requirementModel, duty, quantity and destination.
  2. Review the configurationResolve ratings, interfaces and site conditions.
  3. Agree the technical scheduleScope, drawings, tests, price and delivery terms.
  4. Confirm delivery documentsAgree packing, identification and the applicable inspection records.

Testing, warranty terms and after-sales scope are to be agreed in the quotation and order documents for the selected configuration.

Product catalogue

Mingkong Transformer Selection Guide · Updated 24 October 2026 · Chinese / English

Download PDF ↗

For a quotation, include your required model, rating, quantity and operating conditions.

Plan your enquiry

Use these guides to prepare the information for equipment selection and quotation.